The Cionic Neural Sleeve is bionic clothing that combines the diagnostic power of a gait lab with the therapeutic power of Functional Electrical Stimulation (FES) into a lightweight, durable (and stylish) garment that **can be worn anywhere** **and work everywhere.**

## Cionic Neural Sleeve TM Can Assist With:

• **Improved walking** for individuals with:

− Multiple Sclerosis

− Cerebral Palsy

− Stroke

− Incomplete Spinal Cord Injury

− Traumatic Brain Injury, or

− Other neuromuscular diagnoses

• **Exercise and muscle conditioning** for individuals with leg weakness

through the Cionic app

## Combines Function & Form

• First-of-its-kind Read + Write Neural Interface for measuring and activating

• Easy-to-don sleeve and software-steerable stimulation provide

## Advanced Technology:

• Coordinated FES activation  
   quadriceps, hamstrings during gait

• Algorithms that continuously measure user movement and adapt to individual needs

*The Cionic Neural Sleeve is an FDA*  
    
*cleared Class II Medical device*  
   
*FDA Clearance K213622*

## Rigorously Tested in Trials

94% of participants

90% of participants inversion during swing

9° average improvement to dorsi+inversion across all participants

---

# Technical Specifications

Neural Sleeve

| Clonic Neural Sleeve NS-100 |  |
| --- | --- |
| Classification | Internally powered, continuous operation with Type BF applied parts |
| Power Source(s) | Lithium Polymer (LiPo) rechargeable 7.4V 1900mAh |
| Controls | Single button |
| Indicators | Single LED indicator |
| Operating Modes | Exercise & Assist |
| Number of Output Channels | 1 stimulator channel with 8 virtual Positive output channels and 15 virtual Negative output channels |
| Number of EMG (input) Channels | 8 |
| EMG Sampling Rate | 2kHz |
| EMG detection(Bipolar/Monopolar) | Bipolar |
| Waveform(e.g., pulsed monophasic,biphasic) | Pulsed Monophasic with hybrid stimulation |
| Regulated Current or Regulated Voltage | Regulated Current |
| Charging System | Medical Class II Power Adapter Input:100-240V~50/60HzOutput:5V2Ausing USB-C cable |
| Weight | Control unit(DC-100):145gSleeve(SL-100):S2230g,S4240g,S6250g |
| Dimensions[W×H×D] | Control unit(DC-100):137x53x24mmSleeve(SL-100)S252x61cm,S458x63cm,S669x68cm |
| Waveform | Pulsed Monophasic with hybrid stimulation |
| Shape | Rectangular |
| Maximum Output Voltage | 135V |
| Maximum Output Current | 100mA@500Ω,65mA@2kΩ,13mA@10kΩ |
| Current | 0 to 100mA at 5mA increments |
| Pulse Width | 100 to 400μs at 100μs increments |
| Frequency | 5-100Hz at 5Hz increments |
| Maximum Intensity | 24.6mA(rms) |
| Maximum Load | Maximum load:300Ω |
| Minimum Load | Minimum load:22kΩ |
| Sizes | 52,54,56 |
| Materials | Control Unit(DC-100):Injection Molded Plastic(medical grade polycarbonate(Makrolon))with encased electrical componentsSleeve(SL-100):84%Polyester16%LycraSleeve(SL-100) Sensors:Injection Molded Plastic(medical grade polycarbonate(Makrolon))with encased electrical components |
| Environmental Ranges | Transport and storage temperature:-4°Fto+140°F(-20℃to+45℃)Operating conditions temperature:41°Fto104°F(5°Cto40°C)Charging temperature:41°Fto104°F(5°Cto40°C)Relative humidity:10%to75%Operating humidity:15%to93%Shipping pressure:20kPa to106kPaOperating pressure:70kPa to106kPa |

**CIONIC, Inc.**  
1606 Stockton St. Suite #1 San

**fax: +1 (510) 426-7572**